Description
AUTO mode for performing a sequence of measurements
Large measurement memory: 100 objects with 40 cells each
SPESIFIKASI
PVM-1020 | Specifications
Parameter | Measurement range | Display range | Resolution | Accuracy |
---|---|---|---|---|
Voltage | ||||
AC voltage | 0.0 V…600.0 V | 0.0 V…600.0 V | 0.1 V | ±(2% m.v. + 2 digits) |
DC voltage | 0.0 V…1000.0 V | 0.0 V…1000.0 V | 0.1 V | ±(0.5% m.v. + 2 digits) |
Short circuit current ISC | 0.0…20.0 A | 0.0…20.0 A | 0.1 A | ±(1% m.v. + 2 digits) |
Insulation resistance | ||||
Insulation resistance at AC side | ||||
Measuring voltage 250 V | 250 kΩ…2.000 GΩ acc. to IEC 61557-2 | 0.0 kΩ…2.000 GΩ | from 0.1 kΩ | ±(3% m.v. + 8 digits) |
Measuring voltage 500 V | 250 kΩ…5.000 GΩ acc. to IEC 61557-2 | 0.0 kΩ…5.000 GΩ | from 0.1 kΩ | ±(3% m.v. + 8 digits) |
Measuring voltage 1000 V | 500 kΩ…9.999 GΩ acc. to IEC 61557-2 | 0.0 kΩ…9.999 GΩ | from 0.1 kΩ | ±(3% m.v. + 8 digits) |
Insulation resistance at DC side | ||||
Measuring voltage 250 V / 500 V / 1000 V | 250 kΩ…1.000 GΩ acc. to IEC 61557-2 | 0.0 kΩ…1.000 GΩ | from 0.1 kΩ | ±(3% m.v. + 8 digits) |
Resistance of protective conductors and equipotential bondings | ||||
Measurement of resistance of protective conductors and equipotential bondings with ±200 mA current | 0.10 Ω…1999 Ω acc. to IEC 61557-4 | 0.00 Ω…1999 Ω | from 0.01 Ω | ±(2% m.v. + 3 digits) |
Measurement of resistance with low current | 0.0 Ω…1999 Ω | 0.0 Ω…1999 Ω | from 0.01 Ω | ±(3% m.v. + 3 digits) |
Current measurement | 0.0 A…400.0 A | 0.0 A…400.0 A | from 0.01 Ω | ±(5% m.v. + 2 digits) |
Power measurement | 0.0 kW…100.0 kW | 0.0 kW…100.0 kW | 0.1 kW | ±(6% m.v. + 5 digits) |
“m.v.” – measured value
IRM-1 | Specifications
Parameter | Measurement range | Display range | Resolution | Accuracy |
---|---|---|---|---|
Irradiance | ||||
Measurement in W/m2 | 0 W/m2 …1400 W/m2 | 0 W/m2 …1400 W/m2 | 1 W/m2 | ±(5% m.v. + 2 digits) |
Measurement in BTU/ft2 h | 0 BTU/ft2 h…444 BTU/ft2 h | 0 BTU/ft2 h…444 BTU/ft2 h | 1 BTU/ft2 h | ±(5% m.v. + 2 digits) |
PV and ambient temperature | ||||
Measurement in °C | -20.0°C…100.0°C | -20.0°C…100.0°C | 0.1°C | ±(1% m.v. + 5 digits) |
Measurement in °F | -4.0°F…212.0°F | 4.0°F…212.0°F | 0.1°F | ±(1% m.v. + 5 digits) |
Inclination angle | -90°…+90° | -90°…+90° | 1° | ±2° |
Position direction – compass | 0°…360° | 0°…360° | 1° | ±5° |
“m.v.” – measured value
AUTO mode for performing a sequence of measurements
Large measurement memory: 100 objects with 40 cells each
WhatsApp us
Reviews
There are no reviews yet.